  Nexxus SV750 Fiber Optic Illuminator Nexxus Starpro Fiber Optic Illuminator Nexxus Fiberpro Fiber Optic Illuminator Nexxus SV150T Fiber Optic Illuminator Nexxus Eclipse II Fiber Optic Illuminator Nexxus LyteLaunch 150 Fiber Optic Illuminator
  SV750 Starpro Fiberpro SV150T Eclipse II LyteLaunch 150
Lamp 75 watt
quartz halogen
70 watt
3000 K metal halide
150 watt
metal halide
150 watt
4000K metal halide
250 watt
4200K metal halide
150 watt
4200K metal halide
Electronic Rating 120 VAC
• 60 Hz
• 0.7 Amps
220 VAC
• 50 Hz
• 0.40 Amps
120 VAC
• 60 Hz
• 0.9 Amps
220 VAC
• 50 Hz
• 0.45 Amps
120 VAC, 60 Hz
• 4.5 A (start up)
120 VAC, 60 Hz
• 2.3 A (running)
220-240 VAC
• 50 Hz
• 3.5 A (start up)
220-240 VAC
• 60 Hz
• 2.0 A (running)
120 VAC
• 60 Hz
• 3 A (start up)
120 VAC
• 60 Hz
• 1.8 A (running)
220-240 VAC
• 50 Hz
• 3 A (start up)
220-240 VAC
• 50 Hz
• 1.2 A (running)
120 VAC
• 60 Hz
• 4.6 A
220 VAC
• 50 Hz
• 3 A
277 VAC
• 60 Hz
• 2.5 A
120V / 240V / 277V
Power Consumption 88 watts max. 100 watts max.
300 Watts max. 200 Watts max. 600 watts max. 180 watts max.
FIber Capacity 2500 fibers
• w/.75mm fibers
2500 fibers
• w/0.75mm fibers
500 fibers
• w/ 0.75mm fibers
288 fibers
• Ultra SideGlow®(1mm)
550 fibers
• w/.75mm fibers
288 fibers
• Ultra SideGlow 1mm
756 fibers
• .75mm
435 fibers
• Ultra SideGlow (upgrade) 1mm
500 fibers
• 0.75mm
288 fibers
• 1mm
670 fibers
• 0.75mm
380 fibers
• 1.00mm
132 fibers
• 1.50mm
74 fibers
• 2.00mm
32 fibers
• 3.00mm
Safety Features Internal 122˚F/ 50˚C thermal protector
Power inlet 2 map fuse (extra fuse provided)
Internal 185°F/ 85° C thermal protector Internal 185°F/ 85° C thermal protector Internal 185°F/ 85° C thermal protector Internal 185°F/ 85° C thermal protector Thermally protected ballast and kill switch when cover is opened
Operation Temperature -20˚F to 110˚F
(-29˚C to 44˚C)
-20°F to 110°F
(-29°C to 44°C)
-20°F to 110°F
(-29°C to 44°C)
-20°F to 110°F
(-29°C to 44°C)
-20°F to 110°F
(-29°C to 44°C)
-20°F to 110°F
(-29°C to 44°C)
Dimensions 5.5” X 9.5” X 5.75”
140mm X 241mm X 146mm
add 11” (279.4mm) for fiber head and fiber to “W” position
8.25” W* x 12.5” L x 6.5” H (209mm x 318mm x 165mm)
add 15” (381mm) for fiber head and fiber to “W” position.
8.5”(W) x 14.625” (L) x 6.125” (H)
216mm x 372mm x 156mm
14.125”H (359mm) with door open
Allow an additional 5” (127mm) for fiberhead and fiber to “W” position
9.5” x 9.5” x 20”
241mm x 241mm x 508mm
12” W* x 13.80” L x 7.13” H
305mm x 353mm x 181mm
add 18.6” (472mm) for fiberhead and fiber to “W” position
11.0” (l) x 6.5” (w) x 7.75” (h)
270.4 mm (l) x 165.0 mm (w) x 196.8 mm (h)
Weight 7 lb (3.2 kg) 7 lb (3.2 kg)
23 lb (10.5 kg) 21 lb (9.5 kg) 27 lb (12.2 kg)
8lbs (3.6 kg)
DMX version:
10lbs (4.5 kg)
Finish Powder coating, no bare metal, inside or outside Powder coating, no bare metal, inside or outside, water, corrosion and chemical resistant Galvanneal, Powder coating, no bare metal inside or outside, Water, corrosion and chemical resistant
UV stabilized materials, water, corrosion and chemical resistant Galvanneal
Powder coating, no bare metal, inside or outside
Water, corrosion and chemical resistant
Formed CRS housing, powder coat finish
Standard Feature On-Off power and color wheel switch On/off power and color wheel switch On/off power and color wheel switch On/off power and color wheel switch On/off power and color wheel switch On/off power and color wheel switch
Installation Surface or wall mount
Horizontal for OUTDOOR and WET location Surface or wall mount
Must be flush mounted to surface for proper air separation between compartments.
Surface or burial mount up to area below fan location. Surface or wall mount-horizontal fiberhead direction only. Must be flush mounted to surface for proper air separation between compartments  
Ventilation 21 CFM enclosure cooling 6” (152mm) clearance required to nearest surface. 24” (610mm) clearance required between each illuminator 115 CFM enclosure cooling
Recommended distance from surface, 6”(152mm)
Recommended distance from another light source, 24”(509mm)
115 CFM enclosure cooling
28 CFM fiber tunnel cooling
Recommended distance from surface, 6”
Recommended distance from another light source, 24”
Forced ventilation 115 CFM, FAN: 20 Watts, 80,000 hrs. lamp life 6” clearance required to nearest surface. 2’ clearance between each illuminator. 115 CFM enclosure cooling
60m3/h fiber tunnel cooling
56 CFM fan cooled
Standards UL / cUL UL / cUL UL / cUL UL / cUL UL / cUL UL/cUL
IP Rating 20 23 23 23 23 65
dB Rating 40dbA 50dbA FiberPro:52dbA
FiberPro-Q:35dbA
48dbA 56dbA 28dbA
Lamp Rated Life 4,000 hours 9,000 hours 10,000 hours 10,000 hours 4,000 hours 6,000 hours
UL Listed Dry location UL file No. E166626 Wet & Dry Locations (Wet location, the unit must face up)
UL file No.E202257
Wet and dry locations
UL file No.E202257
for Wet Locations
UL file No. E202257
Wet & Dry Locations (Wet location unit must be installed horizontal face up)
UL file No. E202257
Wet and dry locations UL file No. E202257
Warranty 2 years on parts (excluding lamp) 2 years on parts (excluding lamp) 2 years on parts (excluding lamp) 2 years on parts (excluding lamp) 2 years on parts (excluding lamp) 2 years on parts (excluding lamp)
  SV750 Starpro Fiberpro SV150T Eclipse II LyteLaunch 150
Specification Sheets view view view view view view
Manual view view view view view view
 

Copyright ©2022深圳市光鼎电子有限公司 ▪  tel:86-755-82683588  /13302949480